ELD TEST PLAN · CASE BOARD

Electronic Logging Device (ELD) Test Plan and Procedures · Version 2.1 (7/18/2017) · Federal Motor Carrier Safety Administration
This board is generated from a weekly test run of the shipped code. Run 2026-08-24 · fingerprint 841bdbd.
Integrity details
source SHA256 483149d66b50… · registry payload SHA256 e72f3ab42328… · repo HEAD 841bdbd · generated 2026-08-24 22:53 UTC
results 2026-08-24T22:16:47.494807+00:00
271 of 314 passing (86.3%)
1NOT-RUN 1PASS FAIL 1FINDING 1HARDWARE-OWNED 1OPERATIONAL 1N/A-BY-ELECTION
Green = genuinely passing. Yellow = a known gap we're still working on. Grey = not yet tested, or handled by the hardware/not applicable to us. Tap any pill to see the exact federal requirement.
How scoring works
Only a real pass counts as green. We don't round up. A yellow pill is a requirement we've written a test for but haven't met yet; it's committed and visible, and if it ever started passing on its own without us noticing, the board would flag it red so a fix can never sneak in unverified. Grey pills are cases with no test of their own (hardware's responsibility, an operational step, or not applicable to our configuration) or cases simply not yet run.

ELD-1.1 · ELD – Accounts

15 / 18 passing
123456789101112131415161718

ELD-1.2 · ELD – Inputs

60 / 73 passing
12345678910111213141516171819202122232425262728293031323334353637383940414243444546474849505152535455565758596061626364656667686970717273

ELD-1.3 · ELD – Vehicle Interface

0 / 1 passing
1

ELD-2.1 · ELD – Processing

60 / 60 passing
123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960

ELD-2.2 · ELD – Monitoring

41 / 48 passing
123456789101112131415161718192021222324252627282930313233343536373839404142434445464748

ELD-2.3 · ELD – Recording

44 / 47 passing
1234567891011121314151617181920212223242526272829303132333435363738394041424344454647

ELD-3.1 · ELD-Outputs

37 / 41 passing
1234567891011121314151617181920212223242526272829303132333435363738394041

ELD-3.2 · ELD-Data Transfer

14 / 26 passing
1234567891011121314151617181920212223242526
Share X Facebook
All 314 cases accounted for: every test named, failures included.
Integrity details
collected 14575 testcases · joined 274 case results · ignored 14266 non-case results (0 failing)
registry 314 == board 314 · per-procedure 18/73/1/60/48/47/41/26
census (committed terminal-state law): 214 GREEN · 3 XFAIL-FINDING · 57 ALREADY-ASSERTED · 27 HARDWARE-OWNED · 4 OPERATIONAL · 9 N/A-BY-ELECTION = 314 · NOT-RUN 0
40 node-less cases rendered from the census (owner states: 27 hardware-owned · 4 operational · 9 n/a-by-election)